ADS1102CAL+ DIGITAL ANALOG OSCILLOSCOPE
Product Name:ADS1102CAL+ DIGITAL ANALOG OSCILLOSCOPE

Product No:15238-245
Model:
Special Price: 372US Dollar/pcs
Last update:2011.07.03
Manufacturer:ANTTEN
   Products Introduction

PRODUCTS  FEATURES

Dual channel - channel bandwidth: 25MHz, 60MHz, 100MHz, 150MHz

The volume exquisite and it is convenient for carrying

Use Colored TFT LCD, the waveform display is clearer and stable

The real time sampling rate is 500MSa/

Memory depth of ADS1000 is 4K and that of ADS1000M is 2M

Trigger Modes: Edge, Pulse, Video, Slope, Alternative and Delay trigger modes

Front and Back USB Host/Device, GPIB

Unique Digital Filter function and Waveform recorder function

Waveform recorder function

Pass/Fail function

Thirty two parameters Auto measure function

Cursor measure covers Manual mode, Track mode and Auto mode

Channel waveform and it's FFT waveform display on split screen

Pop-up Menu display pattern is more convenient for users using it

Multiple Language User Interface

Support multilingual online help

FUNCTIONS OVERVIEW

   

ABUNDANT TRIGGER FUNCTION

ADS1000 series products have rich trigger modes: Edge, Pulse, Video, Slope, Alternative and Delay trigger mode, which will satisfy with users¡¯ more extensive needs. Alternative trigger mode is usually used to observing two non-correlated signals at the same time and users can select different trigger mode for two channels, which is a kind reproduction that analog oscilloscope function in the digital oscilloscope.

 

Edge Trigger

Video Trigger

Pulse Trigger

Alternate Trigger

 
 
FFT WAVEFORM SPLIT DISPLAY FUNCTION

 

FFT waveform and its Channel waveform can display on split screen at the same time. In split display mode, the screen is divided into two parts and each part is divided eight divides in vertical direction. That is similar to under the entire screen pattern simultaneously to observe two waveforms. This way will make users observe waveforms to be clearer and convenient.

   
POP-UP MENU DISPLAY MODE
 

ADS1000 series use pop-up menu display mode. The menu may hide as necessary make waveforms display on 12 divides full screen. Comparing with other same level digital oscilloscopes, this kind of pattern is more flexible, the user operation is more convenient and users can observe waveforms clearly.

 

   
AUTO MEASURE FUNCTION
 

ADS1000 series can auto measure thirty two parameters, which is most in the same level digital oscilloscopes. Auto measure function can eliminate user error consumedly, and users will measure parameters what they need faster and more accurately using it. ADS1000 series also have an all measurement function that displays all the waveform parameters on the screen according to measure kinds, and users can ready measure parameters value expediently. So ADS1000 series are your most perfect measure tools in current market.

 

   
DIGITAL FILTER FUNCTION
 

ADS1000 series provide a digital filter function, and users can use it setting upper limit and lower limit of frequency to reduce signal noise and filter error signal. So they can observe their interested signals distinctly, which will advance users¡¯ work efficiency consumedly. 

 

Digital Filter function turned OFF

Digital Filter function turned ON

   
   
WAVEFORM RECORDER FUNCTION
 

Using this function, Users can continue record data of their need signals as the form of frame. Waveform recorder can record input waveform from CH1 and CH2, with maximum record length of 1500 frames. This record behavior can also be activated by the pass/fail test output, which makes this function especially useful to capture abnormal signals in long term without keeping an eye watching it.

 

 

   
PASS/FAIL FUNCTION
 

Users may use the Pass/Fail function that the ADS1000 series provides to carry on the product test. Through a series of setups, the oscilloscope can output the test result automatically which enhanced the product production efficiency greatly.

 

 

   
EASYSCOPE SOFTWARE (STANDARD)
 

Enlarge Image

EasyScope3.0 software is the powerful system softwaresuitable for ADS1000 series products. This software can becompatible RS-232 and USB Device to realize communication between the computer and the oscilloscope, then realizeslong-distance control. Simultaneously this software can automatic real-time refresh waveform data, provide waveformsmeasure datasampling data, screen images read¡¢storage and printing functions. In addition,EasyScope3.0 also has setups upload and download function.Most quickly basing on millisecond level interactive between PC and ADS1000 series make users to be easier to analyze, research waveforms and data.

 

weight :4.5KG

If you need it, please contact sales@1bu8.com and  xitonghan@139.com